Sign In | Join Free | My ecer.co.uk
China Shenzhen Jutai Comm Co., Ltd. logo
Shenzhen Jutai Comm Co., Ltd.
J - Journey U - Unrivaled T - Tech A - Advancement I - Innovation
Verified Supplier

3 Years

Home > Loop Detector >

LD-200 LD-202 Dual Channel Vehicle Loop Detector AC DC Versions for Parking Barrier and Direction Detection

Shenzhen Jutai Comm Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

LD-200 LD-202 Dual Channel Vehicle Loop Detector AC DC Versions for Parking Barrier and Direction Detection

LD-200 Power : 100-240VAC

Model Number : LD-200

Frequency Levels : High / Medium-High / Medium-Low / Low

Price : Negotiation

LD-202 Power : 12-24VAC/DC

Certification : CE

Frequency Range : 20-100kHz

Auto Reset Time : 10 Minutes in Normal Mode

MOQ : 1

Delivery Time : 5 - 8 working days

Working Modes : 6 Selectable Modes

Detection Technology : Inductive Loop Vehicle Detection

Payment Terms : T/T,L/C,D/A,D/P,Western Union,Paypal,Alipay

Sensitivity Range : 0.015% to 0.8%

Place of Origin : China

Sensitivity Levels : 8 Levels per Channel

Relay Outputs : CH1 COM/NO; CH2 COM/NO

Supply Ability : 1000 pieces per month

Detection Channels : 2 Channels

Brand Name : JUTAI

Loop Inputs : CH1 Loop + CH2 Loop

Packaging Details : Cartoon

Contact Now

LD-200 LD-202 Dual Channel Vehicle Loop Detector AC DC Versions for Parking Barrier and Direction Detection
Product Overview
LD-200 LD-202 Dual Channel Vehicle Loop Detector AC DC Versions for Parking Barrier and Direction Detection

The LD-200 / LD-202 series provides the same dual-channel vehicle detection concept in two supply versions. LD-200 is designed for 100-240VAC power, while LD-202 uses 12-24VAC/DC. This allows a parking-system integrator to select the detector that matches the power available inside the barrier or access-control cabinet without changing the basic dual-loop operating concept.

Both versions accept two inductive loops, CH1 and CH2, and can be used for independent vehicle presence detection or for directional logic when the loops are arranged in sequence. The series is therefore suitable for parking barriers, access-control entrances, exit lanes and other projects that require two detection zones.

Key Features
  • Two independent loop inputs
  • Vehicle direction detection
  • Six selectable working modes
  • Presence and pulse relay operation
  • Eight sensitivity levels per channel
  • Four frequency selections across approximately 20-100kHz
  • Automatic reset and permanent presence modes
  • Trailer sensitivity increase function
  • LED-based detection and loop-fault indication
Model Selection Guide

Choose LD-200 when the control cabinet provides 100-240VAC. Choose LD-202 when the available supply is 12-24VAC/DC. The selection should be based on the project power architecture and wiring requirements. Other vehicle-detection functions remain based on the same dual-channel principle described in the series manual.

Technical Specifications
Parameter Specification
Series LD-200 / LD-202
Detection Channels 2
LD-200 Power 100-240VAC
LD-202 Power 12-24VAC/DC
Loop Inputs CH1 + CH2
Sensitivity 8 levels each channel
Sensitivity Range 0.015%-0.8%
Frequency 20-100kHz
Frequency Options High / Medium-High / Medium-Low / Low
Selectable Modes 6
Direction Detection Yes
Independent Presence Detection Yes
Pulse Output Logic Yes
Auto Reset Approx. 10 min
Permanent Presence Yes
Trailer Sensitivity Function Yes
Relay Outputs CH1 COM/NO; CH2 COM/NO
Installation Reference
Loop Perimeter Recommended Turns
3-4m 6 turns
4-6m 5 turns
6-10m 4 turns
10-20m 3 turns
20m and above 2 turns

For a typical dual-loop direction-detection layout, CH1 and CH2 are installed as separate sensing loops in sequence along the lane. The manual illustration shows approximately 1m between the two loops. After installation, the detector should be reset whenever DIP-switch settings are changed.

Connection Diagram
LD-200 LD-202 Dual Channel Vehicle Loop Detector AC DC Versions for Parking Barrier and Direction Detection
Indicators and Status Monitoring
  • Power LED (RED): Illuminates to indicate "Power ON"
  • CH1 Detection LED:
    • Steady On: Vehicle detection
    • Slow Blinking: Loop short circuit or insufficient twists
    • Fast Blinking: Loop open circuit or excessive twists
  • CH2 Detection LED:
    • Steady On: Vehicle detection
    • Slow Blinking: Loop short circuit or insufficient twists
    • Fast Blinking: Loop open circuit or excessive twists
Sensitivity Configuration

Sensitivity and frequency adjustment is facilitated through 7-way and 10-way dip switch settings:

  • 8 different sensitivity settings available via dip switch configuration
  • Dip switches 6, 7, and 8 govern CH1 sensitivity (0.8 to 0.015)
  • Dip switches 3, 4, and 5 control CH2 sensitivity (0.8 to 0.015)
LD-200 LD-202 Dual Channel Vehicle Loop Detector AC DC Versions for Parking Barrier and Direction Detection
Switch Configuration Details

Switch 1 (S1) - Channel 1 Loop Function Selection:

  • DIP 1 & DIP 2: Special Sensitivity Increase For Both Trailer (Both Channels)
  • D3, D4, D5 and Switch 2 D1, D2: Special Functions (Mode1, 2, 3 Direction Detection. Mode 4, 5, 6 Normal mode)
  • D6 & D7 & D8 and Switch 2 D3 & D4 & D5: CH1 and CH2 Sensitivity Selection (Eight Levels)
  • D9 & D10 and Switch2 D6, D7: Frequency Selection (20 K to 100 KHz)
LD-200 LD-202 Dual Channel Vehicle Loop Detector AC DC Versions for Parking Barrier and Direction Detection LD-200 LD-202 Dual Channel Vehicle Loop Detector AC DC Versions for Parking Barrier and Direction Detection LD-200 LD-202 Dual Channel Vehicle Loop Detector AC DC Versions for Parking Barrier and Direction Detection LD-200 LD-202 Dual Channel Vehicle Loop Detector AC DC Versions for Parking Barrier and Direction Detection
Reset Button Note: The LD-200 must be reset every time a setting change is made to the Dip switches.
Installation Guidelines
  • Coil cutting size should be rectangle: length 1.0 to 2.0 meters, width 0.8 to 1.2 meters
  • Avoid right angles at corners as much as possible
  • Use ferromagnetic wires for induction coil, total length up to 500 meters
  • Keep product plug and socket in vertical direction during installation
LD-200 LD-202 Dual Channel Vehicle Loop Detector AC DC Versions for Parking Barrier and Direction Detection LD-200 LD-202 Dual Channel Vehicle Loop Detector AC DC Versions for Parking Barrier and Direction Detection
System Integration

The JUTAI LD200/202 double-channel vehicle loop detector series, equipped with direction recognition function, is ideal for single-channel entry and exit scenarios when integrated with:

  • JUTAI One door controller (Model: AC-11)
  • JUTAI gate barrier (Model: BR-110)
  • JUTAI long-range RFID reader (Model: PUHF-9)
  • High-temperature resistance loop coils (Model: JTHT-11)
LD-200 LD-202 Dual Channel Vehicle Loop Detector AC DC Versions for Parking Barrier and Direction Detection
Working Principle
Entry Process
  1. Car enters community/parking lot, pressing two loop coils simultaneously
  2. LD-200/202 triggers UHF reader at entrance
  3. UHF reader reads card ID and sends to controller via Wiegand output
  4. Controller verifies ID validity and outputs relay signal to open gate barrier
  5. Car enters, barrier arm lowers automatically
  6. LD-100/102 provides safety and anti-smashing functionality
Exit Process
  1. Car exits community/parking lot, passing inside UHF reader
  2. LD-200/LD-202 triggers UHF reader to read card and send ID to controller
  3. Controller verifies ID validity and outputs relay signal to open gate barrier
  4. Car exits, barrier arm lowers automatically
  5. LD-100/102 provides safety and anti-smashing functionality
Direction Recognition

The Direction Recognition Function ensures the double channels loop detector does not trigger the signal again when the car passes another UHF reader, recording only entry or exit records in the system.

LD-200 LD-202 Dual Channel Vehicle Loop Detector AC DC Versions for Parking Barrier and Direction Detection
Independent Operation Mode

The JUTAI LD-200/202 Double Channel Loop Detector can also function as two independent single-channel loop detectors, suitable for standard one-in and one-out parking lots.

This configuration provides cost-saving benefits by reducing hardware costs associated with using separate detectors for each function.

LD-200 LD-202 Dual Channel Vehicle Loop Detector AC DC Versions for Parking Barrier and Direction Detection
Application Examples
LD-200 LD-202 Dual Channel Vehicle Loop Detector AC DC Versions for Parking Barrier and Direction Detection LD-200 LD-202 Dual Channel Vehicle Loop Detector AC DC Versions for Parking Barrier and Direction Detection
Typical Applications
  • Parking barrier gates with AC-powered control cabinets
  • Low-voltage DC/AC parking controllers
  • Entrance and exit direction detection
  • Two-loop vehicle access lanes
  • Commercial parking systems
  • Residential and industrial vehicle gates
Integration Value

Offering both AC and low-voltage supply versions gives distributors and integrators flexibility across different barrier brands and project standards. The common dual-channel logic also makes it easier to standardize lane design while choosing the appropriate power model for each installation.


Product Tags:

dual channel loop detector

      

vehicle loop detector for parking barrier

      

AC DC loop detector for direction detection

      
Quality LD-200 LD-202 Dual Channel Vehicle Loop Detector AC DC Versions for Parking Barrier and Direction Detection for sale

LD-200 LD-202 Dual Channel Vehicle Loop Detector AC DC Versions for Parking Barrier and Direction Detection Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shenzhen Jutai Comm Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)